Thorough periodic inspection and testing of homes, rental properties and business premises, with a clear written EICR at the end.
An Electrical Installation Condition Report tells you, in writing, whether the fixed wiring in a building is safe to keep using. Ayan Electricians carries out every EICR in Watford and across Hertfordshire and North West London ourselves, for homeowners, private and social landlords, letting agents and businesses.
Wiring does not fail all at once. Insulation dries out, connections loosen, accessories crack, and over the years people add sockets, lights and garden circuits that were never tested. A periodic inspection finds those problems before they show up as a burning smell, a tripping board or a shock from a metal tap.
We inspect and test to BS 7671, the IET Wiring Regulations, and record every circuit we check. You get a report that lists each observation with a code, explains what it means in plain English, and tells you whether the installation is satisfactory or unsatisfactory. If anything needs putting right, we quote for it in writing first.
We start at the consumer unit. Before any testing, we check the board itself: the condition of the enclosure, whether the protective devices suit the cables they protect, whether there is RCD protection where the regulations expect it, and whether the main earth and bonding to gas and water pipes are present and sized correctly.
Next we test. Each circuit is isolated in turn and checked for continuity of the protective conductors, insulation resistance between conductors, correct polarity and earth fault loop impedance. RCDs are tripped with a test instrument to confirm they disconnect fast enough. Meanwhile we open a sample of sockets, switches and light fittings to look at the terminations behind them, which is where scorching and loose connections tend to hide.
The power has to go off circuit by circuit, so we agree the timing with you in advance. For a typical two or three-bedroom house, expect us to be on site for around half a day. Larger homes, flats with communal supplies and commercial premises take longer, and we will give you a realistic time when we book.
Every observation on the report carries a code, and the codes decide the overall outcome.
Any C1, C2 or FI makes the report unsatisfactory. C3s alone do not. We never upgrade a C3 to a C2 to sell work. If you are a landlord, the remedial work and confirmation process is explained on our Landlord Services page.
Call 01923 372423 or send the form for a free, no-obligation quote on your periodic inspection and test.
The recommended interval depends on who uses the building and how.
Private landlords in England must have the installation inspected and tested at least every five years under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. The same five-yearly standard now applies to social housing, covering new tenancies from 1 December 2025 and existing tenancies from 1 May 2026.
Owner-occupied homes are recommended to have an inspection at least every 10 years, and whenever the property changes hands. For buyers, a report before exchange gives you facts to negotiate with.
Commercial premises are typically inspected every five years, although the inspector may set a shorter interval for workshops, kitchens or buildings with heavy use. Many businesses book the EICR alongside PAT Testing so all the electrical safety records are updated in a single visit.
Your report will state the recommended date for the next inspection.
For landlords, the paperwork matters as much as the testing. You need to give a copy of the report to existing tenants within 28 days of the inspection, to new tenants before they move in, and to the local authority within seven days if they ask. Where the report requires remedial work, that has to be done within 28 days, or sooner if the report says so, and you then need written confirmation that it has been completed.
We handle that whole loop. Letting agents can book us directly to arrange access with tenants, and we send the finished report digitally so it can be forwarded the same day. If you want a more location-specific overview, see our EICR Watford page.
For shops, offices and industrial units, we schedule testing to suit trading hours, including early starts where needed, so the power is not off when you are serving customers. Ongoing maintenance support is covered on our Commercial page.
Call or use the form. We confirm the property size, number of circuits and access arrangements, then agree a time.
Circuits are isolated one at a time, tested and inspected. Any immediate danger is made safe on the spot.
You get the full EICR with coded observations, test results and a plain-English summary of the outcome.
If the report is unsatisfactory, we provide a written quote, complete the work and issue confirmation paperwork.
For a typical two or three-bedroom house in Watford, the inspection and testing usually take around half a day. The power will be off to individual circuits for short periods, so we agree timings in advance and keep fridge and freezer circuits off for as little time as possible.
It means at least one observation has been coded C1, C2 or FI. It does not necessarily mean the whole installation needs replacing; often it is one or two specific faults, such as missing bonding or a damaged accessory. We explain each item, quote for putting it right and, once the work is done, provide written confirmation that the issues have been resolved.
Yes, in practice. The term “landlord safety certificate” is commonly used, but what the law requires is an Electrical Installation Condition Report showing the installation is satisfactory for continued use. Our /electrical-certificates/ page explains how the EICR differs from other certificates such as an EIC or minor works certificate.
It is not a legal requirement for owner-occupiers, but it is recommended on a change of occupancy and buyers’ solicitors and surveyors increasingly ask about the electrics. For buyers, it gives you an independent picture of the wiring before you commit, which is especially useful on older properties that may need a rewire.
Minor items, such as replacing a cracked socket or missing blanking plate, can often be done during the visit if you agree. C1 dangers are always made safe immediately. Larger remedials, like a consumer unit replacement or new bonding, are quoted in writing so you can decide before anything goes ahead.
Not necessarily. We need access to every room, the consumer unit and the meter position. Many landlords and letting agents arrange for tenants to let us in, or leave keys with us. We will call when we finish to talk through the outcome.
Yes. Our electricians are qualified in inspection and testing, work to BS 7671 and we are Part P registered. Every report we issue can be verified, and we are fully insured for the work we carry out.
Call 01923 372423 or send the form for a free, no-obligation quote on your periodic inspection and test.