Straight answers from our Watford electricians on testing, certificates, landlord rules, installations, EV chargers and security.
These are the electrician FAQs our Watford team hears most often, answered in plain English. They cover booking, inspection and testing, landlord obligations, rewires and fuse boards, EV chargers, CCTV and fire alarms. If your question is not here, or you want advice about your own property, call 01923 372423 or send us a message through the form. Advice is free. You can also browse our Services or check the Areas We Cover.
Call 01923 372423 or 07872 339288, or send the enquiry form with your postcode and a short description of the job. For small repairs we can often agree a price over the phone. For larger work we arrange a survey at a time that suits you, then send a written quote.
For surveys and the start of a job, yes, so we can agree the plan and access. For longer jobs such as rewires, many customers leave us a key once work is under way. For EICRs we need access to every room and the fuse board, which a tenant or agent can provide.
Usually only the circuits we are working on. Some jobs, such as a fuse board replacement, need the whole supply off for part of the day. We tell you in advance how long to expect so you can plan around it, for example by keeping the freezer closed.
Yes. We use dust sheets, vacuum as we go and take away old fittings, cable offcuts and packaging. Where we have to cut into plaster for a rewire or new circuit, we make good the chases ready for decorating unless agreed otherwise in the quote.
Call us. Our workmanship guarantee covers the work we carry out, so if a fault is down to our installation we return and fix it. Faulty equipment is also covered by the manufacturer’s warranty, and we deal with that process for you where we supplied the item.
We visually inspect the installation, then test a sample or all of the circuits depending on the agreed scope. That includes insulation resistance, earth continuity, polarity, earth fault loop impedance and RCD operation. You receive a report listing any defects with a code and an overall satisfactory or unsatisfactory result.
C1 means danger is present and we make it safe before leaving. C2 means potentially dangerous and needs urgent remedial work. C3 means improvement recommended but not a reason for failure. FI means further investigation is needed. Any C1, C2 or FI makes the report unsatisfactory.
The recommended interval for an owner-occupied home is up to 10 years, and on a change of occupancy, such as when you buy a house. It is also sensible after a flood, before major alterations, or if the installation shows signs of age like rewireable fuses or old rubber cable.
If the work was notified under Part P, the building control certificate can often be reissued by the registration scheme or the council. If no records exist, an EICR assesses the current condition and gives you a report you can show a buyer, insurer or solicitor.
A typical flat takes around two to three hours and a three-bedroom house around three to four hours, depending on the number of circuits and how accessible the fuse board and accessories are. Commercial premises vary much more and are scoped before we quote.
Private landlords in England must have the installation inspected and tested at least every five years under the 2020 regulations, or sooner if the previous report says so. The same five-yearly standard now applies to social housing, for new tenancies from December 2025 and existing tenancies from May 2026.
Existing tenants must receive a copy within 28 days of the inspection, new tenants before they move in, and prospective tenants within 28 days of asking. The local authority must be given a copy within seven days of requesting one. Keep a copy for the next inspector.
You must complete the remedial work or further investigation within 28 days, or sooner if the report specifies. Once the work is done you need written confirmation from the electrician, which must be sent to the tenant and the local authority within 28 days of completion.
Yes. Many of our landlord jobs are booked through letting agents. We can arrange access with the tenant, send the report and any quote for remedials to the agent and landlord, and supply the completion paperwork once the work is finished.
Yes. Landlords in England must fit a smoke alarm on every storey used as living accommodation and a carbon monoxide alarm in any room with a fixed combustion appliance, excluding gas cookers. Alarms must work on the first day of each tenancy and be repaired once reported faulty.
A full rewire of an occupied three-bedroom semi usually takes between five and ten working days for the electrical work, depending on access, the number of circuits and whether floors are carpeted or boarded. Plastering and decorating follow afterwards. We give you a stage-by-stage plan before we start.
Warning signs include rewireable fuses, black rubber or fabric-covered cable, round-pin sockets, scorch marks, frequent tripping and lights that flicker. Age alone is not proof. An EICR is the reliable way to find out whether you need a full or partial rewire, or just targeted repairs.
Older boards often lack RCD protection, which cuts the power quickly if someone touches a live part or there is a leakage to earth. A modern consumer unit with RCBOs and surge protection is safer and makes faults easier to trace. We also check earthing and main bonding at the same time.
New circuits, consumer unit replacements and work in special locations such as bathrooms are notifiable under Part P. Because we are Part P registered, we self-certify the work and notify building control for you, so you do not need to apply separately.
Often, yes. If the existing circuit is in good condition and has capacity, we can extend it and issue a minor works certificate. If it is overloaded, old or lacks RCD protection, we will explain the options, such as a new dedicated circuit.
Most homes can, but we check the incoming supply, main fuse rating, earthing arrangement and the route from the fuse board to the parking space first. Some properties need load management or a fuse upgrade from the network operator, which we explain before quoting.
Yes. Under the smart charging regulations, chargers sold for home use in Great Britain must have smart functionality, such as scheduled off-peak charging and demand response. We install compliant smart chargers and set up the app with you on the day.
The government OZEV chargepoint grant may be available if you rent or own a flat. Eligibility rules change, so we will check whether you’re eligible for a government OZEV grant before quoting rather than assume either way. If you do qualify, we explain what paperwork is needed. See our /ev-charger-installation/ page for more.
We can only install a charger on land you own or control with off-street parking. Running a cable across a public pavement is not safe or permitted. If you have no driveway, your council may offer on-street charging options instead.
Yes. We install workplace and commercial chargers for staff, fleet and visitor parking. We assess the building’s supply capacity first, then design the layout and load management, and certify the installation when complete. Work can be scheduled outside trading hours. Our /commercial-electrician/ page covers the wider work we do for businesses.
Yes. The IP and HD systems we install include remote viewing through an app, so you can check live footage and recordings from anywhere with a data connection. We set up the app on your phone and show you how to find and export footage before we leave.
If your cameras only capture your own property, UK GDPR does not normally apply. If they capture beyond your boundary, such as the street or a neighbour’s garden, ICO guidance applies and you have responsibilities. We position cameras and use privacy masking to keep coverage focused.
IP cameras give higher resolution and easier remote viewing, and suit new installations. HD-TVI and analogue HD can reuse existing coaxial cable, which makes them a cost-effective upgrade for older systems. We recommend whichever suits your property and budget after looking at what is already there. More detail is on our /cctv-cameras/ page.
Homes, including most rented flats and houses, follow BS 5839-6. Workplaces, shops, offices and the common parts of many residential blocks follow BS 5839-1. The required system category should come from your fire risk assessment, and HMOs may have extra council licensing conditions. Our /fire-alarms/ page explains the options for each type of building.
Most smoke and heat alarms should be replaced about 10 years after manufacture, and carbon monoxide alarms according to the manufacturer’s stated lifespan, typically 7 to 10 years. The date is printed on the alarm. Test them monthly with the button.
Tell us about the job and we will come back to you with advice and a free, no-obligation quote.