Old fuse boxes replaced with modern consumer units, giving RCBO protection, surge protection and correct earthing in a single visit.
The consumer unit, or fuse board, is the control centre of your electrics. When something goes wrong on a circuit, it is the board that cuts the power before a cable overheats or someone gets a shock. Ayan Electricians provides fuse board replacement in Watford and across Hertfordshire and North West London, replacing old fuse boxes and early consumer units with modern, metal-clad boards built to current standards.
Plenty of homes still have a board with rewirable fuses, a plastic enclosure, or a single RCD covering half the house. Those set-ups may have been acceptable when they were fitted, but they offer far less protection than a modern board, and they are a common reason for C2 and C3 observations on an EICR.
A board change is more than swapping a box on the wall. Before connecting anything, we test every circuit, because a new board with sensitive RCD protection will expose faults the old one ignored. We also check your earthing and bonding and put right anything that does not meet BS 7671.
You do not need to replace a board simply because it is old, but there are clear reasons to upgrade:
An EICR is the best way to find out whether your board is a priority. If you already have a report with C2 or C3 codes relating to the board, see our EICR & Inspection page for what those codes mean.
An older-style dual RCD board splits circuits into two groups, each protected by one RCD. If one circuit has a fault, every circuit on that side trips. That is why a faulty kettle can take out the fridge freezer and the upstairs lights at the same time.
RCBOs combine a circuit breaker and an RCD in a single device for each circuit. A fault on one circuit only switches off that circuit, leaving the rest of the house running. They cost more than a dual RCD board, but for most homes they are the better choice, and we will always show you both options in the quote.
Surge protection devices (SPDs) protect your installation and connected equipment against transient overvoltages, such as those caused by lightning strikes on the network or switching on the grid. The regulations require an assessment of whether surge protection is needed, and in most domestic installations it is now included. With TVs, routers, boilers and smart appliances all containing sensitive electronics, it is a sensible addition.
Talk to a qualified Watford electrician for free advice and a written quote. Call 01923 372423 or send the form.
A new consumer unit relies on a sound earth to work properly. Before we fit a board, we check the main earthing conductor from your supply, its size and condition, and the main protective bonding to incoming gas and water pipes.
In older homes, it is common to find bonding missing altogether, undersized, or disconnected after a plumber replaced a section of pipe. We also come across earthing that has been compromised by previous alterations. Those are not optional extras; without them, protective devices may not disconnect a fault quickly enough, so we include any necessary upgrades in the quote.
On some properties, particularly where the supply earth is unreliable, an earth electrode may be required. We test and explain the result rather than guessing.
Most domestic fuse board replacements are completed in a single day. We arrive, explain what will happen, and test the existing circuits. The power is then switched off while we remove the old board, fit the new one, connect each circuit to its own protective device and upgrade earthing and bonding as needed.
Plan for the power to be off for most of the working day. Fridges and freezers will be fine if you keep the doors closed, and we will let you know when you can turn things back on. If testing uncovers a fault on a circuit, such as a damaged cable, we explain what we found, make it safe and agree how to deal with it before going further. That is far better than leaving a new board that keeps tripping.
Replacing a consumer unit is notifiable work under Part P. You receive an Electrical Installation Certificate, and we notify building control through our Part P competent person scheme. If your wider wiring is in poor condition, our House Rewiring page explains the alternatives. For a sudden fault, see our Emergency Electrician service, or Contact Us to book a free assessment.
We look at your existing board, earthing and bonding, and discuss any planned work such as showers or EV charging.
You receive a clear quote showing RCBO and dual RCD options, surge protection and any bonding upgrades.
Circuits are tested, the old board is replaced and earthing upgraded, usually in a single day.
Final testing is completed, you receive your certificate and the work is notified to building control.
Most domestic consumer unit replacements are completed in a single working day, with the power off for most of that time. If pre-installation testing reveals faults on existing circuits, such as damaged cables, additional time may be needed to repair them. We explain any findings and agree the next steps with you.
It depends on the number of circuits, whether you choose RCBOs or a dual RCD board, whether surge protection is required, and the condition of your earthing and bonding. After a free assessment we give you a written, itemised quote so you can compare options.
A modern board with RCD protection detects earth leakage that an old fuse box ignored. Persistent tripping usually means there is a genuine fault, such as moisture in an outdoor socket, a damaged cable or a faulty appliance. We test circuits before fitting to find these problems early, and can trace faults on existing boards too.
Current regulations require consumer units in domestic premises to be made of non-combustible material, which in practice means a metal enclosure. Existing plastic boards do not automatically need replacing, but any new or replacement board we fit will comply with this requirement.
Yes. Replacing a consumer unit is notifiable work in England. It must be carried out by a competent person, tested, certified and notified to building control. As a Part P registered contractor, we handle the notification and you receive an Electrical Installation Certificate and a Building Regulations compliance certificate.
Both meet the regulations. A dual RCD board is cheaper, but a single fault can switch off half the house. RCBOs give each circuit its own protection, so a fault only affects the circuit concerned. For most family homes RCBOs are worth the extra, and we will price both options for you.
Talk to a qualified Watford electrician for free advice and a written quote. Call 01923 372423 or send the form.